The readers were fine. The lights weren't.
In 2018 we were installing HF RFID readers in a university library in Madinah, and the readers simply wouldn't behave.
Noise on every floor ranged from 300 to 950 mV, far too high for reliable reads. Then we put the same reader in an area with no LED lights. Noise dropped below 20 mV and it worked perfectly.
The cause was the lighting. Low-cost LED drivers that aren't designed to EMI limits such as EN 55015 can swamp an HF RFID field.
What I took from it
- Survey the site's electrical environment before installation, not after
- Put lighting and other EMI sources on the pre-installation checklist
- When a proven system fails in one building, look at what's different about the building
Often the problem isn't in the system you're installing. It's in everything around it.